Expanded metal specification sheets use a set of shorthand terms, SWM, LWM, strand width, mesh thickness, that are rarely explained by other suppliers. If you're an architect writing a spec, a contractor checking a delivery, or a QS comparing supplier quotes, understanding what these measurements mean is the difference between ordering the right panel and ordering the wrong one. This guide explains each technical term, how they relate to each other, and what they mean in practice for facade, screen, and structural applications in Singapore.
Key Terms in Expanded Metal Spec Sheet

Short Way of Mesh (SWM)
SWM means short way of mesh. In the Webforge terminology, it is a corresponding knuckle-to-knuckle distance across the short direction: a mesh pitch, not the clear opening. The clear short-way opening is labelled SWO. Supplier conventions can differ, so use the labelled drawing for the selected profile.
SWM controls how dense the mesh looks when viewed straight-on. A low SWM produces a fine, tight mesh with small visible apertures. A high SWM produces an open mesh where the diamond pattern is clearly visible from a distance.
For facade screening applications, SWM is the measurement most relevant to visual privacy, the lower the SWM, the less you can see through the panel at a given viewing distance.
Long Way of Mesh (LWM)
LWM means long way of mesh. In the same convention it measures corresponding knuckle-to-knuckle points along the long direction; LWO is the clear long-way opening. Ask whether each quoted dimension is a pitch or an opening, and label the panel orientation rather than relying on the order of two numbers.
Mesh geometry and orientation matter to panel behaviour, but LWM alone cannot establish structural suitability. For walkways or other load-bearing applications, confirm the selected profile, support span, frame, fixings, design loads and deflection limits with the responsible project engineer.
Strand Width (SW)
SW is the width of each individual metal strand that forms the mesh. It is measured across the flat face of the strand.
Strand width is the primary indicator of panel weight and material density. A fine mesh with 1.5mm strands will be significantly lighter than a structural mesh with 5mm strands at the same sheet thickness. For facade panels where self-weight affects the fixing design, SW is the figure your structural engineer will want alongside the sheet thickness.
Sheet Thickness (ST)
Check whether a thickness value describes the starting sheet, finished strand or overall raised mesh height. These are different measurements; flattening can change the finished dimensions. Record the stated convention when comparing drawings and quotations.
Open Area
Open area describes the proportion of the mesh face that is open rather than metal. Use the selected profile's declared percentage and measurement convention. A quick estimate can help initial comparisons, but a few nominal dimensions do not establish every raised or flattened profile's actual open area.
Open area directly affects: solar heat gain through a facade screen, airflow through a ventilated panel, visual transparency at different viewing distances, and acoustic performance when used as a ceiling or screen. For BCA Green Mark projects, open area feeds into ETTV calculations for facade screening elements.
How Open Area Is Estimated
For an initial comparison, MAISHI's technical guide gives a quick approximation based on short-way pitch and strand width. It is not a universal manufacturing formula or a substitute for the selected supplier's drawing.
Approximate open area (%) = (1 − 2 × strand width ÷ short-way pitch) × 100
Expanded Metal Open Area Estimate
Use the short-way centre-to-centre pitch and strand width from the same supplier drawing, both in millimetres. Do not enter a clear opening in the pitch field. This quick approximation is for initial comparison; confirm the selected product's declared open area before ordering.
Both values must be positive, and the pitch must be greater than twice the strand width.
Enter both dimensions, then calculate.
Manual example: for a 20 mm pitch and 3 mm strand width, (1 − 2 × 3 ÷ 20) × 100 = 70%. This is an illustrative estimate, not a Supply Bay product specification.
Raised or flattened geometry, tolerances and unmeshed borders can change the actual result. Open area alone does not establish airflow, solar shading, acoustic performance, load capacity or safety. Use the selected product data and project assessment for those decisions.
Common Expanded Metal Profiles and Their Typical Specs
The ranges below illustrate profile groupings; they are not certified product dimensions or load ratings. Confirm the chosen drawing, whether SWM/LWM denote pitch or clear openings, and the declared open area before comparing or ordering.
| Product | SWM (mm) | LWM (mm) | SW (mm) | ST (mm) | Approx. Open Area | Typical Use |
|---|---|---|---|---|---|---|
| Fine mesh | 4 to 8 | 8 to 16 | 1.0 to 1.5 | 0.8 to 1.2 | 25 to 35% | Interior screens, close-view facade infill, decorative panels |
| Medium mesh | 10 to 20 | 20 to 40 | 2.0 to 3.0 | 1.2 to 2.0 | 35 to 45% | Exterior facade screens, car park cladding, rain screens |
| Louver mesh | 20 to 35 | 40 to 70 | 3.0 to 4.0 | 1.5 to 2.5 | 40 to 52% | Ventilated facades, M&E plant room screens, louvre systems |
| Walkway / heavy mesh | 25 to 50 | 50 to 100 | 4.0 to 8.0 | 3.0 to 6.0 | 45 to 55% | Walkway grating, access platforms, structural facade panels |
| Anti-climb mesh | 6 to 12 | 12 to 20 | 3.0 to 5.0 | 2.0 to 3.0 | 20 to 30% | Security fencing, perimeter screens, anti-climb barriers |
What to Check When Comparing Quotes from Different Suppliers
Suppliers don't always use identical product codes. Two panels described as "medium expanded metal mesh" can have different specs. When comparing quotes, verify:
Labelled short- and long-way dimensions: confirm pitch versus clear opening, units and orientation against the selected drawing. A shared product name does not establish identical geometry or open area.
Strand width, a lower SW at the same mesh size means lower weight and reduced structural performance.
Sheet thickness.
Alloy grade, 1100 and 5052 are both aluminium but have different corrosion resistance; SS304 and SS316 are both stainless steel but perform differently in coastal conditions.
Frequently Asked Questions
-
SWM and LWM identify the short and long directions of the mesh. In a common manufacturer convention they are knuckle-to-knuckle pitches; SWO and LWO describe clear openings. Confirm the selected supplier's labelled drawing because a pitch and an opening are not interchangeable.
-
Expanded metal panels have a directional orientation, the long way of mesh runs in one direction. If panels are installed rotated 90° from the intended orientation, the visual pattern will look different even though the material is identical. On facade applications where visual alignment matters, confirm the panel orientation with the supplier before fabrication and mark the installation direction on delivery.
-
Item Supply Bay provides full technical data sheets for all expanded metal profiles, including SWM, LWM, SW, ST, weight per m², and open area percentage. Contact us at info@supplybaystore.com.
Supply Bay Pte Ltd supplies expanded metal mesh for facade, cladding, and structural applications across Singapore. Contact us at info@supplybaystore.com or +65 6524 3913.

Supply Bay is Singapore's leading supplier of architectural sheet metal, expanded mesh, perforated panels, laser-cut screens, and solid sheets in aluminum, stainless steel (SS304, SS316), mild steel, and galvanized steel.