Expanded mesh, perforated and laser cut panels for feature ceilings, acoustic ceilings and open ceilings in shops, F&B, hotels and offices. Metal does not sag in humid air conditioned rooms, and panels lift out for M&E access.

| Ceiling | Look | Open area | Sound | Typical rooms |
|---|---|---|---|---|
| Expanded mesh | Semi transparent diamond texture | 30 to 55% | Moderate, with backing | Retail, hospitality, feature zones |
| Perforated panel | Flat face with a regular hole pattern | 20 to 65% | High, with acoustic backing | Offices, meeting rooms, F&B, schools |
| Laser cut panel | Any custom pattern | By design | By design | Feature ceilings, design led fit outs |
They mix well: a laser cut feature zone inside a perforated ceiling, or expanded mesh over one zone and perforated panels over another.
Use perforated panels with mineral wool or glass wool above them. Sound passes through the holes into the backing, which cuts echo. Aim for at least 20 to 25% open area; below 15% the panel reflects sound whatever is behind it.
Metal does not absorb moisture, so it does not sag or stain in Singapore's humid, air conditioned rooms. Panels come down and go back up for M&E maintenance without damage. Expanded mesh is also lighter than perforated sheet over the same span, which means less load on the ceiling grid.
Heavy expanded mesh also works out of sight. At Chick-fil-A Bugis+, W50-075 walkway mesh was installed above the finished ceiling as a rigid base for the suspended ceiling and the M&E services.


Yes. Metal ceiling panels do not absorb moisture, so they do not sag or deform in humid, air conditioned spaces the way gypsum board or mineral fibre tiles can.
Yes, with perforated panels and a mineral wool or glass wool backing above them. Use at least 20 to 25% open area; below 15% the panel reflects sound regardless of the backing.
Fine expanded mesh is the usual choice for retail and hospitality ceilings. ION Food Opera uses F15-20 aluminium expanded mesh and the Golden Goose store at Paragon uses F20-15.
Yes. Metal ceiling panels can be removed and reinstated for M&E maintenance without damage.
Yes. Laser cut panels follow any vector file to plus or minus 0.1mm, on sheets up to 3000mm x 1500mm, with the pattern lining up across neighbouring panels.
GuideMetal Ceiling Systems Singapore: Specifier's Guide for Architects and ContractorsMetal ceiling systems for Singapore retail, office, F&B, and institutional projects. Expanded mesh, perforated panels...
View
GuidePerforated Metal vs Mineral Fibre Tiles: Acoustic Ceiling Guide for Singapore ProjectsChoosing between perforated metal and mineral fibre tiles for an acoustic ceiling in Singapore? This guide compares NRC...
View
GuideLaser-Cut Metal Panels Singapore: Specifier's Guide for Architects and ContractorsThis guide covers everything you need to know before placing a laser cut order, materials, thicknesses, file...
View